Export product-family resource

Standalone Smoke Alarms for Hainan Wireless Fire Alarm

Use Standalone Smoke Alarms for Hainan Wireless Fire Alarm to compare Wanlin model paths, project inputs, evidence boundaries and export enquiry requirements.

Direct answer

What does standalone detection mean?

An export standalone smoke alarm detects smoke and provides a local audible warning without requiring a conventional fire alarm control panel. For OEM sourcing, buyers should first define the protected space, required local alarm behaviour, reporting method, power arrangement and destination-market evidence.

This page is written for importers, distributors and private-label procurement teams. It is a product-family selection resource, not a claim that every variant has the same approval, radio module or market access.

WANLIN-307 connected standalone smoke alarm reference for OEM sourcing

Model reference image

Review the exact configuration, not only the family name

The image identifies a WANLIN-307 family reference. Radio, power, label and evidence scope can differ by controlled configuration; confirm the SKU/BOM before using any formal product or compliance statement.

Open the WANLIN-307 product passport · Review the public evidence center

Verified manual data

WANLIN-307 documented configuration

Evidence scope: WANLIN-307 user manual, Ver 1.0. Documented manual configuration only; radio, platform, power and market variants require separate SKU/BOM confirmation.

Parameters transcribed from the supplied WANLIN-307 user manual
Detection principleInfrared photoelectric smoke sensing with MCU processing
Rated working voltageDC 3 V
Battery capacity2400 mAh
Standby current≤ 6 μA
Alarm current≤ 100 mA
Sound pressure> 80 dB(A) at 3 m directly in front
Operating temperature−10 °C to +50 °C
Relative humidity≤ 95% RH at 40 °C ± 2 °C
Alarm outputAudible and visual alarm
Low-voltage indicationBelow 2.7 V; indicator and one chirp about every 40 s
Normal indicatorIndicator illuminates about every 40 s
Approximate weight140 g including battery
Manual-listed execution standardGB 20517-2006
Installation referenceGB 50116-2013; final layout must follow project design requirements

Important: “GB 20517-2006” is presented here as the execution standard stated by this manual. This wording is not a third-party certificate claim and does not establish destination-market acceptance. The manual also advises against use where relative humidity exceeds 95%, air speed exceeds 5 m/s, or heavy dust, water mist, steam, oil mist or corrosive gas is present.

Site-specific planning lens

How does Hainan Wireless Fire Alarm Systems affect selection?

For this site's OEM sourcing focus, the planning lens is “Hainan Wireless Fire Alarm Systems.” Avoid selecting from a catalogue name alone. Record the application, expected operating environment, power strategy and reporting workflow before comparing models.

A procurement team should request a configuration-controlled quotation rather than a family name without its hardware and communication details.

Existing site context: Wanlin Fire provides Hainan Wireless Fire Alarm Systems, with product selection guidance, technical specifications, OEM/ODM support and project supply for global buyers. Use that context to define the application; it does not replace model-specific technical or compliance review.

A family-level brochure is useful for selection but is not proof that every radio, enclosure, battery or sensor configuration has identical market acceptance.

433 MHz, LoRa, 4G and NB-IoT describe different communication paths; they are not interchangeable labels and may change the hardware, infrastructure and regulatory review.

Last reviewed: 2026-11-02 · Reviewed by Wanlin Fire Equipment for product-family and evidence-boundary consistency.

Which evidence should an importer request?

  1. Identify the destination market
  2. Freeze the exact configuration
  3. Match evidence to the configuration
  4. Review labels and instructions
  5. Approve the production reference

How do the Wanlin model families differ?

WANLIN-303

Standalone photoelectric smoke alarm family

Review standalone, 433 MHz, LoRa or 4G candidates only after the exact hardware and radio version is identified.

WANLIN-307

Connected standalone smoke alarm family

Candidate configurations may include standalone, 433 MHz, LoRa, 4G or NB-IoT; availability and evidence must be confirmed per SKU/BOM.

WANLIN-309

Wireless reporting smoke alarm family

Use when the project requires a local alarm plus a defined reporting path; verify gateway, network and destination-market requirements.

WANLIN-370

Combination alarm reference

A smoke/heat/carbon-monoxide combination concept is not interchangeable with a smoke-only alarm; confirm the required sensing functions first.

Answers for buyers

Standalone smoke alarm questions

What evidence should an importer review before ordering?

Request the current product specification, model and configuration record, applicable certificate or test report, certificate holder and scope, validity status, label artwork and destination-market compliance review.

How should connected alarms behave during a network outage?

The project team should document local alarm behaviour, event buffering or retry expectations, supervision, user notification and the party responsible for restoring connectivity.

What should be included in an OEM smoke alarm enquiry?

Include the destination market, application, quantity, sensing function, radio or network path, power preference, packaging language, branding scope and required evidence.

What should be checked during sample approval?

Check model marking, sensing function, alarm behaviour, communication path, power arrangement, gateway or platform interaction, label artwork, manual revision and the evidence pack.

Should importers approve the label before production?

Yes. Review the exact model, legal manufacturer or certificate holder where applicable, ratings, warnings, destination language and document references before production artwork is released.

Request a model-specific export review

Send the destination country, application, quantity, reporting method, preferred power arrangement and required delivery schedule to wanlinfirecontrol@163.com. Recommendations and formal claims remain subject to exact-model evidence review.

Browse product information · Read technical FAQs · Contact Wanlin Fire